CHECK PROPEL GEARBOX OIL LEVEL - Continued
CHAPTER 15. MAINTENANCE--EVERY 500 HOURS

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  209    210    211    212    213  214  215    216    217    218    219  
img
TM 5-3805-280-10
Maintenance--Every 250 Hours
INSPECT ELEMENT
IMPORTANT: A damaged or dirty element may cause
engine damage.
Install a new primary element:
1. If the element shows damage.
2. If element will not clean.
3. After 1000 hours service or annually.
Install a new secondary element:
1. If the primary element is damaged
and needs to be replaced.
2. If the element is visibly dirty.
3. After 1000 hours service or annually.
DO NOT clean a secondary element.
Install a new element carefully centering
it in the canister.
1. Inspect element and gasket for damage.
2. Air restriction indicator will not signal correctly if an
element has a break or is not correctly sealed in air
cleaner housing. Throw away element that has the
slightest damage. If gasket is broken or missing, install
a new element.
03T,55,C67 1924JUL911/1