CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS - Continued
CHECK PROPEL GEARBOX OIL LEVEL - Continued

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  207    208    209    210    211  212  213    214    215    216    217  
img
TM 5-3805-280-10
Maintenance--Every 250 Hours
CHECK PROPEL GEARBOX OIL LEVEL
1. Park the machine on level ground rotating propel
gearbox until bottom of the oil level check plug is even
with the horizontal centerline.
2. Lower bucket to the ground.
3. Turn auto-idle switch off.
IMPORTANT: Turbocharger may be damaged if
engine is not properly shut down.
4. Run engine with engine rpm dial at 1/3 position without
load for 2 minutes.
5. Move engine rpm dial to slow idle position.
6. Turn key switch to OFF. Remove key from switch.
7. Attach a 'Do Not Operate' tag on the right control lever.
8. Pull pilot control shut-off lever to locked position.
Continued on next page
TX,75,DH5098
1908JUL961/2