TM 5-3805-280-10
Maintenance--Every 250 Hours
2. Fill each cell to within specified range with distilled
water. DO NOT overfill.
CAUTION: Avoid possible injury. Always
remove grounded (-) battery clamp first and
replace it last.
3. Disconnect battery clamps, grounded clamp first.
A--Battery Post
B--Fill Tube
C--Electrolyte Level Range
TX,75,DH5594
1905MAY942/3
4. Clean battery terminals (A) and clamps with a stiff
brush.
5. Apply lubricating grease (B) around battery terminal
base only.
6. Install and tighten clamps, grounded clamp last.
7. Install battery covers and hold-down clamps.
TX,75,DH5594
1905MAY943/3
14-7