REPLACING ROCK DRILL DUST COLLECTOR FILTERS
Pressurization air oiler

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  258    259    260    261    262  263  264    265    266    267    268  
img
TM 5-3805-280-10
DAILY MAINTENANCE HYDRAULIC
DUST COLLECTOR
1
Start up the collector.
At low temperatures affecting hydraulic oil
viscosity, let diesel motor warm up before
starting the dust collector.
2.
After start-up of the dust collector,
first thing that happens, is that a
free cleaning cycle automatically
runs.When compressor produces
correct working pressure - allow
further one cleaning cycle without
drilling.
3.
Check that your dust collector
sucks properly by looking at the
rubber dump valve (or plastic bag)
which shall QUICKLY AND
STRONGLY be sucked up against
dust collector bottom.
4.
Check that GASKET in pick up
hood A) and SKIRT B) are not
worn out.
5.
Check that suction hose is not
damaged or bent.
6.
Every day before stopping
machine:
Clean filters as described under point
2 above