OPERATOR STATION CHECKS--KEY SWITCH ON, ENGINE OFF
OPERATOR STATION CHECKS--ENGINE ON

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  294    295    296    297    298  299  300    301    302    303    304  
img
TM 5-3805-280-10
Operational Checkout
FLUID LEVEL
Engine OFF.
YES: Go to next check.
(COOLANT, HYDRAULIC
OIL, AND ENGINE OIL)
Key switch ON.
NO: Check fluid levels in
INDICATOR CIRCUIT
radiator, recovery tank,
CHECKS
hydraulic reservoir, or
Push and hold level check switch (A).
engine. If OK, check fluid
level sensing switch for
Are the hydraulic oil level (B), coolant level (C), and
wiring. Check monitor
engine oil level (D) indicator lights ON?
fuse. If fuse is OK, go to
your authorized dealer.
T107699 UN27FEB97
1/1
YES: Go to next check.
PROPEL LEVER AND
Engine OFF.
PEDAL CUSHION
CYLINDER CHECKS
NO: Go to your
Push each propel lever and pedal forward (A), then
authorized dealer.
release.
Pull each propel lever and pedal rearward (B), then
release.
Does each lever and pedal have equal effort to operate
T7531AO UN07JUN91
forward and reverse?
Does each lever and pedal return to neutral at the same
time when released?
1/1
21-3