OPERATOR STATION CHECKS--KEY SWITCH ON, ENGINE OFF - Continued
OPERATOR STATION CHECKS--ENGINE ON - Continued

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  295    296    297    298    299  300  301    302    303    304    305  
img
TM 5-3805-280-10
Operational Checkout
2 OPERATOR STATION CHECKS--ENGINE ON
1/1
MONITOR CIRCUIT,
Start engine.
YES: Go to next check.
GAUGE CHECKS
Are all monitor indicator lights OFF after engine starts?
NO: Check alternator belt
if battery light is on after
Is coolant temperature gauge needle (A) in normal
engine starts. Go to your
operating zone after a few minutes?
authorized dealer.
Does fuel gauge (B) indicate fuel level?
Stop engine.
T107698 UN27FEB97
1/1
POWER MODE CIRCUIT
Start engine.
YES: Go to next check.
CHECKS
Auto-idle switch OFF.
NO: Check controller
fuse. Go to your
authorized dealer.
Propel speed switch in fast position.
Pilot shut-off lever in LOCKED position.
Push power mode select switches (A) and (B) one at a
time.
Do corresponding indicator lights come on as each
switch is pushed?
T102098 UN26JUL96
1/1
21-4