CHANGE ENGINE RATED SPEED AND ADJUST DROOP--IN-LINE INJECTION PUMPS
HOW THE ANEROID WORKS (IF EQUIPPED)

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  597    598    599    600    601  602  603    604    605    606    607  
img
TM 5-3805-280-24-2
Fuel System Operation and Tests
115
d. Replace access plug in top of governor housing.
75
Start engine, apply full (100%) load, and readjust
high idle adjusting screw until 1500 rpm (50 Hz) is
obtained at the specified power.
e. Screw in idle (bumper) spring until engine speed
increases 5--10 rpm.
7. Repeat Steps 6 (a-d) until governor regulation is within
the 5--7% range.
8. Replace all cap nuts onto adjusting screws and tighten
lock nuts securely.