CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS
CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS - Continued

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  664    665    666    667    668  669  670    671    672    673    674  
img
TM 5-3805-280-24-2
Batteries, Support, and Cables
IMPORTANT: During freezing weather, batteries must
be charged after water is added to
prevent battery freezing. Charge battery
using a battery charger or by running
the engine.
3. Fill each cell to within specified range with distilled
water. DO NOT overfill.
Single Level Fill Tube Application
Dual Level Fill Tube Application
16
A--Battery Post
1671
B--Fill Tube
6
C--Electrolyte Level Range
TX,16,UU3540
1901SEP952/2
USING BOOSTER BATTERIES--24-VOLT
SYSTEM
1. Turn key switch to OFF.
Continued on next page
TX,16,UU3541
1919SEP981/3
16-6