REMOVE AND INSTALL OIL COOLER - Continued
230 REMOVE AND INSTALL LEFT BOOM CYLINDER CONTROLLED LOAD LOWERING VALVE - Continued

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  1029    1030    1031    1032    1033  1034  1035    1036    1037    1038    1039  
img
TM 5-3805-280-24-2
Hydraulic System
2. Retract arm and bucket cylinders. Lower boom so
bucket is on ground.
3. Stop engine.
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
4. Loosen vent plug to release air pressure from hydraulic
oil tank.
Continued on next page
CED,OUOE020,34 1914MAR992/3
33