CHAPTER 14. MAINTENANCE--EVERY 250 HOURS
CHECK PUMP DRIVE GEARBOX OIL LEVEL

Operator Manual For Hydraulic Excavator Model 330Lcr
Page Navigation
  179    180    181    182    183  184  185    186    187    188    189  
img
.
TM 5-3805-281-10
Maintenance--Every 250 Hours
CHECK SWING GEARBOX OIL LEVEL
1. Park machine on a level surface.
2. Remove dipstick (A). Oil must be in the operating
range.
3. If oil is needed, remove filler cap (B) and add oil. (See
Fuels and Lubricants chapter.)
4. Check oil level.
A--Dipstick
B--Filler Cap
TX,75,DH5088
1903JUL961/1
DRAIN HYDRAULIC TANK SUMP
CAUTION: High pressure release of oil from
pressurized system can cause serious burns or
penetrating injury. The hydraulic tank is
pressurized. Do not remove vent plug (A).
Release pressure by loosening vent plug.
1. Loosen vent plug (A) to release hydraulic pressure.
A--Vent Plug
Continued on next page
TX,75,DH5108
1911JUL961/2