CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS
CHECK PROPEL GEARBOX OIL LEVEL

Operator Manual For Hydraulic Excavator Model 330Lcr
Page Navigation
  185    186    187    188    189  190  191    192    193    194    195  
img
TM 5-3805-281-10
Maintenance--Every 250 Hours
2. Fill each cell to within specified range with distilled
water. DO NOT overfill.
CAUTION: Avoid possible injury. Always
remove grounded (-) battery clamp first and
replace it last.
3. Disconnect battery clamps, grounded clamp first.
A--Battery Post
B--Fill Tube
C--Electrolyte Level Range
TX,75,DH5593
1905MAY942/3
4. Clean battery terminals (A) and clamps with a stiff
brush.
5. Apply lubricating grease (B) around battery terminal
base only.
6. Install and tighten clamps, grounded clamp last.
7. Install battery covers and hold-down clamps.
A--Battery Terminals
B--Grease
TX,75,DH5593
1905MAY943/3
14-7