TM 5-3805-281-24-2
Fuel System
TEST AND ADJUST INJECTION NOZZLE
OPENING PRESSURE
CAUTION: `Nozzle tip should always be directed
away from operator. Fuel from spray orifices
can penetrate clothing and skin causing serious
personal injury. Enclosing nozzle in a glass
beaker is recommended.
Before applying pressure to nozzle tester, be
sure all connections are tight and fittings are
not damaged. Fluid escaping from a very small
hole can be almost invisible. Use a piece of
cardboard or wood, rather than hands, to
search for suspected leaks.
If injured by escaping fluid, see a doctor
immediately. Any fluid injected into the skin
must be surgically removed within a few hours
or gangrene may result. Doctors unfamiliar with
this type of injury may call the Deere &
Company Medical Department in Moline, Illinois,
or other knowledgeable medical source.
1. Refer to PERFORM OPENING PRESSURE TEST,
earlier in this group to test nozzle opening pressure.
Adjust opening pressure as needed.
2. Refer to PERFORM NOZZLE LEAKAGE TEST, earlier
in this group to test for leakage. Repair as needed.
3. Refer to PERFORM CHATTER AND SPRAY
PATTERN TEST, earlier in this group to test nozzle
overall operation. Repair as needed.
RG,RG34710,1315