ENGINE SPEED LEARNING PROCEDURE - Continued
ADDING 12-VOLT ACCESSORIES

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  504    505    506    507    508  509  510    511    512    513    514  
img
.
TM 5-3805-281-24-2
Batteries, Support, and Cables
REMOVE AND INSTALL BATTERIES
CAUTION: Prevent personal injury from
exploding battery. Keep sparks and flames
away from battery.
1. Remove wing nuts (A).
2. Disconnect negative (-) battery cables first, then
positive (+) cables.
IMPORTANT: If one battery in a 24-volt system has
failed, replace both batteries.
3. Remove batteries.
Battery--Specification
Voltage........................................................................................... 12 Volts
Cold Cranking Amps ........................................ 1400 amps at -18C (0F)
Reserve Capacity ......................................... 440 minutes at 25 amps and
26.7C (80F)
BCI Group Size ...................................................................................... 4D
Electrolyte Specific Gravity.............................. 1.265--1.280 fully charged
Electrical System--Specification
A--Wing Nuts
Voltage........................................................................................... 24 Volts
TX,16,UU3296
1930SEP941/1
16
1671
14