TM 5-3805-281-24-2
Buckets
WELDING ON MACHINE
33
IMPORTANT: Electrical current traveling from the
3302
welder through the machine electrical
4
system may damage the machine
electrical system, including battery,
EPC controller. Disconnect battery
ground cable and EPC electrical
connectors before welding on the
machine.
Before welding on the machine, follow the steps listed
below to protect the machine electrical system.
TX,16,UU3320
1907JUL981/3
1. Inside the cab, remove four cap screws (A and C) and
the fuse box cover (B) to remove the rear console
cover.
2. Disconnect the battery ground and positive cables.
A--Cap Screw (4 used)
B--Fuse Box Cover
C--Cap Screw (3 used)
Continued on next page
TX,16,UU3320
1907JUL982/3