TM 5-3805-281-24-2
Hydraulic System
IMPORTANT: Hydraulic pump will be damaged if
4. Repair or replace oil cooler bypass valve (K).
not filled with oil before starting.
33
Procedure must be performed to fill
5. Tighten cap screws and nuts on coupling.
3360
pump housing whenever oil has
142
Control Valve-to-Hydraulic Oil Tank Coupling Cap Screw and
been drained from the pump or
Nut--Specification
hydraulic oil tank.
Torque................................................................. 11.4 Nm (100 lb-in.)
7. Do Hydraulic Pump Start-Up Procedure. (See
procedure in this group.)
6. Check oil level in hydraulic oil tank. Add oil as
necessary. (See Hydraulic Oil in Group 0004.)
CED,OUOE027,268
1927MAY983/3
REMOVE AND INSTALL RADIATOR AND OIL
COOLER
CAUTION: Explosive release of fluids from
pressurized cooling system can cause serious
burns.
Shut off engine. Only remove filler cap when
cool enough to touch with bare hands. Slowly
loosen cap to first stop to relieve pressure
before removing completely.
1. Drain coolant from radiator. Approximate capacity is 30
L (8 gal).
2. Drain hydraulic tank. Approximate capacity is 159 L (42
gal).
Continued on next page
CED,OUOE024,216
1918MAY981/3