Figure 1. Coolant Heater Control Panel.
Figure 4. Adjusting Run Time.

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  210    211    212    213    214  215  216    217    218    219    220  
img
.
TM 5-3805-294-10
0034
ADJUSTING COOLANT HEATER TIME AND DAY - Continued
6.
Time (Figure 2, Item 4) and day (Figure 2, Item 7) is set.
END OF TASK
SETTING AND SELECTING COOLANT HEATER PROGRAM
NOTE
The coolant heater control panel can program three start cycle times within a 24-hour
period or one start cycle per day for 7 days. Only one program can be activated at one
time.
Pressing the preset button (Figure 3, Item 8) until memory display is blank will delete
programs in memory.
1.
Press the preset button (Figure 3, Item 8) until the desired program number (Figure 3, Item 9) begins to flash.
4
7
M0
9
3 20:30
8
6
5
HYEX01315
Figure 3. Setting Program.
2.
Press the left arrow button (Figure 3, Item 5) or right arrow button (Figure 3, Item 6) to adjust start time (Figure
3, Item 4) up or down.
3.
When start time (Figure 3, Item 4) is set, wait approximately 5 seconds and day (Figure 3, Item 7) will begin
to flash.
4.
Press the left arrow button (Figure 3, Item 5) or right arrow button (Figure 3, Item 6) to adjust day (Figure 3,
Item 7) up or down.
5.
When day (Figure 3, Item 7) is set, wait approximately 5 seconds and day will stop flashing.
6.
Start time (Figure 3, Item 4) and day (Figure 3, Item 7) is set.
7.
Program number (Figure 3, Item 9) will be displayed.
8.
Repeat Steps 1 through 7 if additional days of programing is desired.
END OF TASK
ADJUSTING COOLANT HEATER RUN TIME
NOTE
The maximum amount of time for the coolant heater will run is 120 minutes.
0034-3