TM 5-3805-294-10
OPERATOR MAINTENANCE
ENGINE WILL NOT CRANK
INITIAL SETUP:
References (cont.)
References
Equipment Condition
Machine safely parked and shut down.
TROUBLESHOOTING PROCEDURE
Table 1. Engine Will Not Crank.
Test or Inspection
Corrective Action
Malfunction
1.
Place pilot shutoff lever in
1.
Pilot Shutoff Lever
LOCK (up) position.
in UNLOCKED
(down) Position.
2.
1.
If engine starts, malfunction
corrected.
2.
If engine does not crank,
proceed to Malfunction 2.
1.
Turn key switch to ON position,
2.
Discharged
but DO NOT START ENGINE.
Batteries.
2.
Observe monitor for battery
3.
Turn key switch to OFF
1.
If monitor displays battery
warning alarm, notify Field
Maintenance.
If monitor does not display
2.
battery warning alarm,
proceed to Malfunction 3.
0047-1