Table 1. Engine Runs Poorly
EXCESSIVE OIL CONSUMPTION

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  239    240    241    242    243  244  245    246    247    248    249  
img
. . . . . . . . . .
TM 5-3805-294-10
0049
OPERATOR MAINTENANCE
EXCESSIVE FUEL CONSUMPTION
INITIAL SETUP:
References (cont.)
References
WP 0077
WP 0005
WP 0087
WP 0009
Equipment Condition
Engine running. (WP 0007)
TROUBLESHOOTING PROCEDURE
Table 1. Excessive Fuel Consumption.
Test or Inspection
Corrective Action
Malfunction
1.
Observe monitor for air cleaner
1.
Air Cleaners Dirty
or Clogged.
clogged alarm. (WP 0005)
2.
1.
If air cleaner clogged alarm is
Shut down engine. (WP 0009)
displayed, remove foreign
objects/debris or replace air
cleaners. (WP 0087)
2.
If air cleaner clogged alarm is
not displayed, proceed to
Malfunction 2.
Visually inspect fuel lines and
1.
If fuel lines or fittings are
2.
Leaking Fuel Lines
fittings for leakage.
leaking, notify Field
and Fittings.
Maintenance.
(WP 0077)
2.
If fuel lines or fittings are not
leaking, notify Field
Maintenance.
END OF WORK PACKAGE