Figure 2. Drain Fuel Filter/Water Separators Continued.
Figure 2. Primary Air Cleaner Removal.

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  341    342    343    344    345  346  347    348    349    350    351  
img
. . . .
TM 5-3805-294-10
0087
OPERATOR MAINTENANCE
PRIMARY AND SECONDARY AIR CLEANER SERVICE
INITIAL SETUP:
Materials/Parts
Equipment Condition
Rag, Wiping (WP 0097, Table 1, Item 15)
Engine off. (WP 0009)
Personnel Required
Time to Complete
Horizontal Construction Engineer 12N (1)
0.4 Hour(s)
REMOVAL
1.
Lift lever (Figure 1, Item 1) and rotate cover (Figure 1, Item 2) counterclockwise.
3
1
2
HYEX00073
Figure 1.
Cover Removal.
2.
Remove cover (Figure 1, Item 2) from air cleaner housing (Figure 1, Item 3).
3.
Remove primary air cleaner (Figure 2, Item 4) from air cleaner housing (Figure 2, Item 3).
0087-1