SERVICING AIR CLEANERS
WARNING
Particles blown by compressed air are hazardous. Ensure air stream is directed away from
user and any personnel in the area. Use a maximum of 30 psi (2.0 bar) when compressed
air is used to clean parts. Always wear safety glasses when using compressed air. Failure to
comply may result in injury or death to personnel.
NOTE
Contact field level maintenance for an air hose and air nozzle to service the air cleaner.
Secondary air cleaner does not require servicing, only replacement.
1.
Lightly tap primary air cleaner (Figure 4, Item 4) to remove major amount of dirt from primary air cleaner.
4
HYEX00076
Figure 4.
Primary Air Cleaner Service.
2.
Start from inside, top of primary air cleaner (Figure 4, Item 4), blow remainder of debris out of primary air
cleaner.
3.
Work around and inward of primary air cleaner (Figure 4, Item 4) until primary air cleaner has been completely
blown out.
4.
Wipe out air cleaner housing (Figure 5, Item 3) with a clean rag.