PRIMARY AND FINAL FUEL FILTER/WATER SEPARATORS SERVICE
PRIMARY AND SECONDARY AIR CLEANER SERVICE

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  340    341    342    343    344  345  346    347    348    349    350  
img
.
TM 5-3805-294-10
0086
DRAIN FUEL FILTER/WATER SEPARATORS - Continued
NOTE
Place drain pan under fuel/water separators prior to draining.
2.
Loosen, but do not remove WIF sensor (Figure 2, Item 2), and drain water/sediment from primary fuel filter/
water separator (Figure 2, Item 3) for approximately 30 seconds.
3
2
1
4
5
HYEX00103
Figure 2. Drain Fuel Filter/Water Separators Continued.
3.
Tighten WIF sensor (Figure 2, Item 2).
4.
Connect wiring harness connector D01 (Figure 2, Item 1) to WIF sensor (Figure 2, Item 2).
5.
Loosen, but do not remove valve (Figure 2, Item 4), and drain water/sediment from final fuel filter/water
separator (Figure 2, Item 5) for approximately 30 seconds.
6.
Tighten valve (Figure 2, Item 4).
END OF TASK
END OF WORK PACKAGE
0086-2