TM 5-3805-294-23-1
0102
Table 1. DTC 1347.07 - Fuel Rail Pressure Actual To Desired Mismatch - Continued.
Test or Inspection
Corrective Action
Malfunction
11.
When finished monitoring,
select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0363)
12.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
13.
Turn key switch to OFF
1.
If readings are within
position (TM 5-3805-294-10).
specifications, proceed to
Malfunction 7.
(Volume 5, WP 0794)
2.
If readings are not within
specifications, proceed to
Malfunction 2.
1.
Disconnect engine wiring
2.
Engine Wiring
harness connector P05 from
Harness Connector
fuel rail pressure sensor.
P05 Has Damage or
Loose Sockets.
(Volume 5, WP 0800, Figure
57)
2.
Visually inspect engine wiring
1.
If damaged or has loose
harness connector P05 for
sockets, repair connector
damage and loose sockets.
P05 (Volume 4, WP 0511) or
replace engine wiring
harness. (Volume 4,
WP 0510) Restore machine to
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
If not damaged and does not
2.
have loose sockets proceed to.
Malfunction 3.
1.
Remove fuel rail pressure
3.
Fuel Rail Pressure
Sensor Has
sensor. (Volume 3, WP 0429)
Damage or Loose
Pins.
0102-3