Table 1. Engine Misfires - Runs Irregularly - Continued
Table 1. Engine Misfires - Runs Irregularly - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  807    808    809    810    811  812  813    814    815    816    817  
img
TM 5-3805-294-23-1
0120
Table 1. Engine Misfires - Runs Irregularly - Continued.
Test or Inspection
Corrective Action
Malfunction
Perform Cylinder
1.
If compression test is within
6.
Mechanical Gauge
Compression Test With
limits, proceed to Malfunction
Cylinder
7.
Compression Test.
Gauge. (Volume 3, WP 0328)
Note readings.
2.
If pressure is too low, replace
cylinder head and/or cylinder
head gasket. (Volume 3,
WP 0407) Restore machine to
original condition.
3.
If pressure is too high, replace
engine. (Volume 3, WP 0410)
Restore machine to original
condition.
1.
Start engine (TM
7.
Fuel Lines Leaking.
5-3805-294-10). (Volume 5,
WP 0794)
2.
Set engine speed and load to
maximum point, if possible.
3.
Inspect all fuel lines and fittings
for leakage.