AIR CONDITIONER/HEATER BLOWER MOTOR RESISTOR/THERMO FUSE REPLACEMENT
Figure 3. Resistor/Thermo Fuse Removal

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  414    415    416    417    418  419  420    421    422    423    424  
img
.
TM 5-3805-294-23-4
0543
REMOVAL - Continued
4
3
2
1
HYEX02339
Figure 1.
Bolt Removal.
2.
Remove two bolts (Figure 2, Item 5), washers (Figure 2, Item 6), and cover (Figure 2, Item 3) from cab (Figure
2, Item 7).
3
7
5
6
HYEX02340
Figure 2. Cover Removal.
3.
Remove wire harness connector R16 (Figure 3, Item 8) from blower motor resistor/thermo fuse (Figure 3, Item
9).