TM 5-3805-294-23-4
0652
BOOM REDUCED LEAKAGE VALVE INSTALLATION - Continued
6.
Install housing (Figure 3, Item 18) to control valve (Figure 3, Item 5) with four screws (Figure 3, Item 17).
7.
Install spring (Figure 3, Item 16) to control valve (Figure 3, Item 5).
8.
Install valve seat (Figure 3, Item 15) to control valve (Figure 3, Item 5).
9.
Lightly lubricate spool (Figure 3, Item 14) with clean oil.
10.
Using a twisting motion, install spool (Figure 3, Item 14) to control valve (Figure 3, Item 5).
11.
Lightly lubricate spool (Figure 3, Item 13) with clean oil.
12.
Using a twisting motion, install spool (Figure 3, Item 13) to control valve (Figure 3, Item 5).
13.
Lightly lubricate backup ring (Figure 3, Item 12) with clean oil.
14.
Install backup ring (Figure 3, Item 12) to spool (Figure 3, Item 8).
15.
Lightly lubricate O-ring (Figure 3, Item 11) with clean oil.
16.
Install O-ring (Figure 3, Item 11) to spool (Figure 3, Item 8).
17.
Lightly lubricate O-ring (Figure 3, Item 10) with clean oil.
18.
Install O-ring (Figure 3, Item 10) to spool (Figure 3, Item 8).
19.
Lightly lubricate backup ring (Figure 3, Item 9) with clean oil.
20.
Install backup ring (Figure 3, Item 9) to spool (Figure 3, Item 8).
21.
Using a twisting motion, install spool (Figure 3, Item 8) to control valve (Figure 3, Item 5).
22.
Lightly lubricate four O-rings (Figure 3, Item 6) and O-ring (Figure 3, Item 7) with clean oil.
23.
Install four O-rings (Figure 3, Item 6) and O-ring (Figure 3, Item 7) to control valve (Figure 3, Item 5).
24.
Install housing (Figure 3, Item 4) to control valve (Figure 3, Item 5) with three screws (Figure 3, Item 3).
25.
Install hose (Figure 4, Item 1) to fitting (Figure 4, Item 2).
0652-5