22
TM 5-2420-232-10
OPERATOR INSTRUCTIONS
-
0006
Slave Starting Machine; Extreme Cold Weather Operation +32 to -25F (0 to -31C); Starting Engine in
Extreme Cold Weather +32 to -25F (0 to -31C); Parking Machine in Extreme Cold Weather Operation
+32 to -25F (0 to -31C); Preparation of Hydraulic System for Operation in Extreme Cold Weather +32
to -25F (0 to -13C); Extreme Hot Weather Operation; Unusual Terrain Operation; Fording Procedures;
Cleaning (Emergency Conditions)
INITIAL SETUP
Materials/Parts
References - Continued
0
0
Oil, lubricating (Item 13, 14, 15, 16, or
FM 31-70
0
FM 31-71
0
0
FM 90-6
0
0
TM 3-4230-214-12&P
Personnel Required
0
0
TM 3-4230-236-10
Two
0
0
0
References
0
0
FM 3-3
0
0
FM 3-4
0
0
FM 3-5
0
0
FM 4-25.11
0
0
FM 9-207
0
0
FM 21-305
0
SLAVE STARTING MACHINE
0006
If the engine does not start due to low or discharged batteries, it can be started with the help of another machine. The HMEE-I
is equipped with an auxiliary power (NATO slave) receptacle.
WARNING
When slave starting machine:
Do not use NATO slave cable that has loose or missing insulation.
Do not proceed if suitable cable is not available.
Do not use civilian-type jumper cables.
Do not allow "dead" and "slave" machines to come in contact with each other at any time during
slave starting.
Do not connect the booster (slave) supply directly to the starter motor. Doing this bypasses the
neutral gear safety switch. If the machine is in gear, it may "runaway" and kill or injure bystanders.
Failure to follow these warnings may cause injury or death to personnel.
0006-1