INSTALL WATER PUMP - Continued
REMOVE AND INSTALL AUTOMATIC (SPRING) BELT TENSIONER

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  339    340    341    342    343  344  345    346    347    348    349  
img
TM 5-3805-280-24-2
Cooling System
COOLING SYSTEM DEAERATION
25
20
Deaeration is normally accomplished by the jiggle pin in
the thermostat flange. However, a pocket of air can stay
on the top rear of the engine. When refilling the cooling
system, loosen the coolant temperature sensor (A) or plug
at the rear of the cylinder head to allow air to escape.
A--Coolant Temperature Sensor
DPSG,OUO1004,19 1903APR981/1
REMOVE AND INSTALL AUTOMATIC
(SPRING) BELT TENSIONER
NOTE: Belt tensioner cap screw (A) is left-hand threaded.
1. Release tension on belts using a breaker bar and
socket.
2. Remove poly-vee belts from pulleys.
3. Remove belt tensioner.
A--Belt Tensioner Cap Screw
Continued on next page
RG,25,JW7552
1920NOV971/2
13-343