TM 5-3805-280-24-2
Batteries, Support, and Cables
REMOVE AND INSTALL 24-VOLT SLAVE
RECEPTACLE
1. Disconnect negative (-) battery cables (A) from battery
(B).
2. Remove cap screws (G) and washers (F).
3. Disconnect cables (C and E).
4. Remove cover (K).
5. Remove cap screws (L) and flange nuts (D).
6. Remove 24-volt slave receptacle (J), backing plate (M),
insulators (I) and cover keeper (H). Replace parts as
necessary.
16
A--Negative (-) Battery Cable
1671
B--Battery
14
C--Positive (+) Cable
D--Flange Nut (4 used)
E--Negative (-) Cable
F--Washer (2 used)
G--Cap Screw (2 used)
H--Cover Keeper
I--Insulator (2 used)
J--24-Volt Slave Receptacle
K--Cover
L--Cap Screw (4 used)
M--Backing Plate
CED,OUOE020,55 1920APR991/1
16-14