INJECTION PUMP FAST AND SLOW IDLE STOPS ADJUSTMENT - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  445    446    447    448    449  450  451    452    453    454    455  
img
.
TM 5-3805-281-24-2
Speed Controls
INJECTION PUMP FAST AND SLOW IDLE
STOPS ADJUSTMENT
1. Connect the tachometer or the laptop computer with
excavator diagnostics program. Select "14 Actual
engine speed" from Monitor Data Items. (See JT05801
Clamp-On Electronic Tachometer Installation in this
group or for laptop computer installation, see
procedure in Group 9025-25.)
2. Start the engine.
3. Warm engine to its normal operating temperature.
4. Stop the engine.
Continued on next page
CED,OUOE003,1084
1908SEP981/4