TM 5-3805-281-24-2
Intake System
1. Disconnect filter restriction indicator switch connector
(A).
2. Loosen clamp (B).
3. Disconnect hose (C).
A--Connector
B--Clamp
C--Hose
TX,05,VV2573 1907JUL981/2
05
4. Remove cap screws (B).
0520
3
5. Remove air cleaner (A).
6. Replace parts as necessary.
7. Install air cleaner.
8. Connect hose and tighten hose clamp.
9. Connector filter restriction indicator switch connector.
A--Air Cleaner
B--Cap Screw (4 used)
TX,05,VV2573 1907JUL982/2