Table 1. DTC 94.03 - Low-Pressure Fuel Signal Out of Range High - Continued.
Table 1. DTC 94.03 - Low-Pressure Fuel Signal Out of Range High - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  83    84    85    86    87  88  89    90    91    92    93  
img
TM 5-3805-294-23-1
0015
Table 1. DTC 94.03 - Low-Pressure Fuel Signal Out of Range High - Continued.
Test or Inspection
Corrective Action
Malfunction
1.
Disconnect engine wiring
17.
Short Circuit
harness connector J01.
Between Engine
Wiring Harness
(Volume 5, WP 0800, Figure
Connector J03
46)
Socket C2 and all
Other Sockets on
Engine Wiring
Harness
Connectors J03 and
J01.
2.
Measure resistance (Volume
1.
If any measurement was less
than 100 kohms, replace
3, WP 0369) between engine
engine wiring harness.
wiring harness connector J03
socket C2 and all other sockets
(Volume 4, WP 0510) Restore
on engine wiring harness
machine to original condition
connectors J03 (Volume 5,
and perform Harness
Diagnostic Mode Test.
WP 0800, Figure 48) and
(Volume 3, WP 0345)
J01. (Volume 5, WP 0800,
Figure 46) Note readings.
2.
If all measurements were
greater than 100 kohms,
proceed to Malfunction 18.
1.
Disconnect engine wiring
18.
Short Circuit
harness connector J02.
Between Engine
Wiring Connector
(Volume 5, WP 0800, Figure
J03 Socket C2 and
47)
all Other Sockets on
Engine Wiring
Harness Connector
J02.
2.
Measure resistance (Volume
1.
If any measurement was less
than 100 kohms, replace
3, WP 0369) between engine
engine wiring harness
wiring harness connector J03
socket C2 (Volume 5,
(Volume 4, WP 0510) and
replace engine interface wiring
WP 0800, Figure 48) and all
harness. (Volume 4,
other sockets on engine wiring
harness connector J02.
WP 0509) Restore machine to
original condition and perform
(Volume 5, WP 0800, Figure
Harness Diagnostic Mode
47) Note readings.
Test. (Volume 3, WP 0345)
2.
If all measurements were
greater than 100 kohms,
reconnect all connectors and
proceed to Malfunction 19.
0015-9