DTC 611.04 - INJECTOR SHORTED TO GROUND
Table 1. DTC 611.04 - Injector Shorted to Voltage Source - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  320    321    322    323    324  325  326    327    328    329    330  
img
TM 5-3805-294-23-1
0048
TROUBLESHOOTING PROCEDURE
Table 1. DTC 611.04 - Injector Shorted to Voltage Source.
Test or Inspection
Corrective Action
Malfunction
1.
Verify key switch is in OFF
1.
Check For DTC
position (TM 5-3805-294-10).
611.04 Active
Status With Engine
(Volume 5, WP 0794)
Wiring Harness
Connector C01
Disconnected.
2.
Disconnect engine wiring
harness connector C01 from
electronic fuel injector harness
connector C01. (Volume 5,
WP 0800, Figure 32)
3.
Turn key switch to ON
position, but DO NOT START
ENGINE (TM 5-3805-294-10).
(Volume 5, WP 0794)
4.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0362)
5.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0362)
6.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0362)
7.
Select Diagnostics tab, then
select Connected Diagnostic
Trouble Codes. (Volume 3,
WP 0362)
8.
Refresh DTCs. (Volume 3,
WP 0362)
9.
Select the Readings tab, then
select Connected Data
Points. (Volume 3, WP 0363)
10.
Under Connected Data Points,
select ECU - (shown with
engine serial number).
(Volume 3, WP 0363)
0048-2