Table 1. DTC 611.04 - Injector Shorted to Voltage Source
Table 1. DTC 611.04 - Injector Shorted to Voltage Source - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  321    322    323    324    325  326  327    328    329    330    331  
img
TM 5-3805-294-23-1
0048
Table 1. DTC 611.04 - Injector Shorted to Voltage Source - Continued.
Test or Inspection
Corrective Action
Malfunction
11.
Under ECU - (shown with
engine serial number), select
ECU - Data List - All. (Volume
3, WP 0363)
12.
Under ECU - Data List - All,
select Fuel Rail Pressure -
Actual. (Volume 3, WP 0363)
13.
Monitor Fuel Rail Pressure.
Pressure should be below 725
psi (5 MPa).
14.
Perform Harness Diagnostic
Mode Test. (Volume 3,
WP 0345)
15.
Refresh DTCs. Many new
DTCs will be active, only note
if DTC 611.04 is an active
DTC. (Volume 3, WP 0362)
16.
Select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0363)
17.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
18.
Turn key switch to OFF
1.
If DTC 611.04 is an active
position (TM 5-3805-294-10).
DTC, proceed to Malfunction
7.
(Volume 5, WP 0794)
2.
If DTC 611.04 is not an active
DTC, proceed to Malfunction
2.
Visually inspect engine wiring
1.
If damaged or has loose
2.
Engine Wiring
harness connector C01 for
sockets, replace engine wiring
Harness Connector
damage and loose sockets.
harness. (Volume 4,
C01 Has Damage or
Loose Sockets.
(Volume 5, WP 0800, Figure
WP 0510) Restore machine to
32)
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
2.
If not damaged and does not
have loose sockets, proceed to
Malfunction 3.
0048-3