Table 1. DTC 611.03 - Injector Shorted to Voltage Source - Continued
Table 1. DTC 611.03 - Injector Shorted to Voltage Source - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  316    317    318    319    320  321  322    323    324    325    326  
img
TM 5-3805-294-23-1
0047
Table 1. DTC 611.03 - Injector Shorted to Voltage Source - Continued.
Test or Inspection
Corrective Action
Malfunction
2.
Measure voltage (Volume 3,
WP 0369) between engine
wiring harness connector J01
socket G2 (Volume 5,
WP 0800, Figure 46) and a
known good ground. Note
reading.
3.
Turn key switch to OFF
1.
If voltage is less than 0.5 volts,
position (TM 5-3805-294-10).
proceed to Malfunction 17.
(Volume 5, WP 0794)
2.
If voltage is greater than 0.5
volts, replace engine wiring
harness. (Volume 4,
WP 0510) Restore machine to
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
Measure resistance (Volume
1.
If any measurement was less
17.
Short Circuit
than 1 kohms, replace engine
Between Engine
3, WP 0369) between engine
wiring harness. (Volume 4,
Wiring Harness
wiring harness connector J01
Connector J01
socket G1 and all other
WP 0510) Restore machine to
Socket G1 and All
sockets on engine wiring
original condition and perform
Other Sockets on
harness connector J01
Harness Diagnostic Mode
Engine Wiring
(Volume 5, WP 0800, Figure
Test. (Volume 3, WP 0345)
Harness Connector
46) EXCEPT the following
2.
If all measurements were
J01.
sockets:
greater than 1 kohms, proceed
Socket A1.
to Malfunction 18.
Socket B1.
Socket C1.
Socket D1.
Socket E1.
Socket F1.
0047-8