Table 1. Engine Does Not Develop Full Power - Continued
ENGINE EMITS EXCESSIVE BLACK OR GRAY EXHAUST SMOKE

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  783    784    785    786    787  788  789    790    791    792    793  
img
TM 5-3805-294-23-1
0116
Table 1. Engine Does Not Develop Full Power - Continued.
Test or Inspection
Corrective Action
Malfunction
2.
Operate engine through
various rpm ranges. (TM
5-3805-294-10) (Volume 5,
WP 0794) Note engine
performance.
3.
Turn key switch to OFF
1.
If engine performance is
position. (TM 5-3805-294-10)
restored, problem corrected.
(Volume 5, WP 0794)
2.
If engine performance was not
restored, it is possible that
another fault exists or that
another troubleshooting
procedure applies. If this was
the first time through this
procedure, restart procedure
at Malfunction 1.
END OF WORK PACKAGE