Figure 1. Monitor Warning Alarm Removal
NEGATIVE BATTERY CABLE DISCONNECT FOR MAINTENANCE TASKS

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  277    278    279    280    281  282  283    284    285    286    287  
img
. . .
TM 5-3805-294-23-4
0520
INSTALLATION - Continued
7
6
5
4
3
1
2
HYEX01130
Figure 2. Monitor Warning Alarm Installation.
2.
Connect cab wiring harness W1 connector H3 (Figure 2, Item 2) to monitor warning alarm connector H3 (Figure
2, Item 1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install rear tray. (WP 0566)
2.
Connect negative battery cable. (WP 0521)
3.
Perform the Standard Follow-On Maintenance Instructions. (Volume 3, WP 0384)
END OF TASK
END OF WORK PACKAGE