TM 5-2420-230-24-1
b. Disassembly.
(0.1) Remove 28 bolts (1), washers (2), hydraulic
reservoir lid (3), and gasket (4) from
hydraulic reservoir (5).
(0.2) Remove hydraulic reservoir sight glass
(1)
Remove six self-locking nuts (6), screws (7,)
and filler neck (8) from hydraulic reservoir
lid (3). Discard self-locking nuts.
(2)
Remove hydraulic oil filter assembly (9) and
fitting (10) from hydraulic reservoir (5).
(3)
Remove fittings (11) and (12) from hydraulic
reservoir (5).
c. Inspection.
Degreasing Solvent (MIL-PRF-680) is toxic and flammable. Keep away from heat or flame. Never
smoke when using solvent. The flashpoint for Type II Degreasing Solvent is 141 F (61 C). Wear
protective goggles, face shield, and gloves; use only in a well-ventilated area; avoid contact with
skin, eyes, and clothes; and do not breathe vapors. Failure to comply may result in injury or death
to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately
flush eyes with water and get immediate medical attention.
Adhesives, solvents, and sealing compounds burn easily and give off vapors that are harmful to the
skin and clothing. To avoid injury or death, keep away from open fire when using these materials,
and use only in well-ventilated areas. If adhesives, solvents, or sealing compounds contact the skin
or clothing, wash immediately with soap and water, and rinse thoroughly. Failure to comply may
result in injury or death to personnel.
Cleanliness is essential for correct and safe operation of hydraulic system. Ensure dirt and debris are
not allowed to enter hydraulic system. Failure to comply may result in damage to equipment.
(1)
Inspect for debris, damage, or contamination. Ensure reservoir is free from all foreign matter. Clean and flush with
degreasing solvent and a clean cloth, as required.
(2)
Inspect rubber strips fitted to chassis and securing straps. Replace as necessary.
d. Assembly.
(1)
Install fittings (11) and (12) on hydraulic reservoir (5).
(2)
Install fitting (10) and hydraulic oil filter assembly (9) on hydraulic reservoir (5).
Change 1
10-16