TM 5-2420-230-24-1
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Tools and Special Tools
Equipment Conditions
TM or Para
Condition Description
Hydraulic reservoir lid
Materials/Parts
removed.
Drawings Required
Personnel Required
MOS 62B, Construction Equipment Repairer
Estimated Time to Complete
a. Removal.
(1)
Deleted.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
(2)
Deleted.
(3)
Reach inside reservoir and remove two nuts and bolts securing sight glass.
(4)
Carefully remove sight glass and O-rings.
b. Installation.
Installation of hydraulic oil reservoir sight glass is the reverse of the removal procedure with attention given to the
following:
Cleanliness is essential for correct and safe operation of the hydraulic system. Ensure dirt and debris
are not allowed to enter hydraulic system. Failure to comply may result in damage to equipment.
(1)
Ensure reservoir is free from dirt and debris by wiping with a clean cloth.
(2)
Deleted.
(3)
Deleted.
c. Follow-On Maintenance.
END OF TASK
Change 1