TM 5-2420-230-24-1
This Task Covers:
a. Removal
b. Installation
c. New Pump Startup Procedure
d. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Personnel Required
None
MOS 62B, Construction Equipment Repairer (2)
References
Tools and Special Tools
None
Equipment Conditions
TM or Para
Condition Description
Firewall cover removed.
Materials/Parts
Center belly plate removed.
Engine access panel removed.
Hydraulic system pressure
released.
Drawings Required
Estimated Time to Complete
a. Removal.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Ensure all hoses and tubes are disconnected and clear before removal.
Remove cable ties as necessary.
Tag all hoses and tubes and note their positions before removal.
Cap and plug all tubes, hoses, and fittings upon removal.
(1)
Disconnect all hydraulic lines on back of hydraulic pump.
(2)
Remove four bolts and lockwashers at pump securing supply line from hydraulic reservoir to hydraulic pump.
(3)
Support pump and remove four bolts, washers, pump, and gasket from transmission. Discard gasket.
(4)
Deleted.