TM 5-2420-230-24-1
10-11. HYDRAULIC RESERVOIR MAINTENANCE.
This Task Covers:
a. Removal
b. Disassembly
c. Inspection
d. Assembly
e. Installation
f. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Personnel Required
None
MOS 62B, Construction Equipment Repairer
Tools and Special Tools
References
Pan, drain, Item 29, Appendix B
None
Tool kit, general mechanics, Item 38, Appendix B
Equipment Conditions
Materials/Parts
TM or Para
Condition Description
Cap and plug set, Item 4, Appendix C
Para 10-9
Hydraulic reservoir drained.
Compound sealing, Loctite 515, Item 21, Appendix C
Para 13-15
Hydraulic reservoir step plate
Compound sealing, Loctite 567, Item 22, Appendix C
removed.
Cloth, lint-free, Item 10, Appendix C
Dexron III, Item 27, Appendix C
Drawings Required
Nut, self-locking, Item 104, Appendix D (2)
TM 5-2420-230-24P Figure 152
Nut, self-locking, Item 108, Appendix D (6)
Solvent, degreasing, Item 58, Appendix C
Estimated Time to Complete
Tags, identification, Item 63, Appendix C
Refer to MAC in Appendix B
Ties, cable, Item 68, Appendix C
a. Removal.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Tag all hoses and tubes and note their positions before removal.
Remove cable ties as necessary.
Cap and plug all tubes, hoses, and fittings upon removal.
(1)
Remove supply and return connections at rear of reservoir.
(2)
Remove bolts and self-locking nuts securing reservoir retaining straps. Discard self-locking nuts.
(3)
Remove hydraulic reservoir.
(4)
Deleted.
Change 1