TM 5-2420-230-24-1
This Task Covers:
a. Removal
b. Disassembly
c. Inspection
d. Assembly
e. Installation
f. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Personnel Required
None
MOS 62B, Construction Equipment Repairer
Tools and Special Tools
References
None
Equipment Conditions
Materials/Parts
TM or Para
Condition Description
Hydraulic reservoir drained.
Compound sealing, Loctite 515, Item 21, Appendix C
Hydraulic reservoir step plate
Compound sealing, Loctite 567, Item 22, Appendix C
removed.
Drawings Required
Estimated Time to Complete
a. Removal.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Tag all hoses and tubes and note their positions before removal.
Remove cable ties as necessary.
Cap and plug all tubes, hoses, and fittings upon removal.
(1)
Remove supply and return connections at rear of reservoir.
(2)
Remove bolts and self-locking nuts securing reservoir retaining straps. Discard self-locking nuts.
(3)
Remove hydraulic reservoir.
(4)
Deleted.
Change 1