TM 5-2420-230-24-1
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
(2)
Disconnect two hydraulic hoses (1) from
stabilizer cylinder (2).
Use care when removing or installing snap and
retaining rings. Snap and retaining rings are
when released and could cause severe eye injury.
(3)
Remove two circlips (3) from bottom pivot
pin (4).
(4)
Remove bottom pivot pin (4) from stabilizer
cylinder (2).
(5)
Remove two circlips (5) from top pivot pin (6).
(6)
Attach suitable lifting device and sling to
stabilizer cylinder (2).
Hydraulic cylinder is heavy. Use an appropriate lifting device and follow safe working procedures when
lifting or moving hydraulic cylinder. Failure to comply may result in injury or death to personnel.
(7)
Remove top pivot pin (6) from stabilizer cylinder (2). Remove stabilizer cylinder.
(8)
Remove fittings as necessary
Change 1