TM 5-2420-230-24-1
(1)
Place drain pan under FEL lift cylinder (1).
Hydraulic fluid (Dexron III) is TOXIC. Wear
protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin,
eyes, and clothes. Skin and clothing that come in
contact with hydraulic oil should be washed
immediately. Saturated clothing should be
removed immediately. Failure to comply may
result in injury to personnel.
(2)
Disconnect hose (2) and check block fitting from
FEL lift cylinder (1).
(3)
Remove two U-bolts (3), nuts (4), and
washers (5) from FEL lift cylinder (1) and
secure check valve to chassis with cable ties.
(4)
Attach suitable lifting device and sling to FEL
lift cylinder (1).
Hydraulic cylinder is heavy. Use an
appropriate lifting device and follow safe
working procedures when lifting or moving
hydraulic cylinder. Failure to comply may
result in injury or death to personnel.
Use care when removing or installing snap and retaining rings. Snap and retaining rings are under
spring tension and can act as projectiles when released and could cause severe eye injury.
(5)
Remove top circlip (6) from top pivot pin (7).
(6)
Remove top pivot pin (7) from FEL lift cylinder (1) and travel stop.
(7)
Remove bottom circlip (8) from bottom pivot pin (9).
(8)
Remove bottom pivot pin (9) from FEL lift cylinder (1).
(9)
Remove FEL lift cylinder (1).
(10) Remove fittings if necessary.
Change 1