TM 5-2420-230-24-1
10-27. HYDRAULIC OIL SAMPLING VALVE REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Equipment Conditions
None
TM or Para
Condition Description
TM 5-2420-230-10
Vehicle positioned on level
ground.
Tools and Special Tools
Tool kit, general mechanics, Item 38, Appendix B
TM 5-2420-230-10
Parking brake applied.
TM 5-2420-230-10
Engine shut OFF.
TM 5-2420-230-10
Electrical master switch OFF.
Materials/Parts
Compound, sealing, pipe thread, Item 22, Appendix C
TM 5-2420-230-10
"Do Not Operate" tag attached
Ties, cable, Item 68, Appendix C
to ignition switch.
Drawings Required
Personnel Required
TM 5-2420-230-24P Figure 157
MOS 62B, Construction Equipment Repairer
Estimated Time to Complete
References
Refer to MAC in Appendix B
None
a. Removal.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Remove cable ties as necessary.
(1)
Disconnect hose (1) from hydraulic oil filter (2).
(2)
Remove oil sampling valve (3) from bracket (4) and adapter (5).
(3)
Remove adapter (5) from hose (1).
Change 1