TM 5-2420-230-24-1
(3)
Remove two nuts (7), lockwashers (8), washers (9), screws (10), and valve assembly (11) from stowage box (12).
Discard lockwashers.
(4)
Remove valve fitting (3) from valve assembly (11).
NOTE
Perform Steps (5) through (7) as necessary for any components that need to be replaced.
(5)
Remove two nuts (13), lockwashers (14), screws (15) and cylinder clamp (16) from stowage box (12). Discard
lockwashers.
(6)
Loosen tube fitting (17), and remove tubing (2) and tube fitting from atomizer (18).
(7)
Remove atomizer (18) from air cross connection (19).
b. Installation.
NOTE
Ensure all hoses, wires, and tubes are reconnected to positions noted prior to removal.
Install cable ties as necessary.
Perform Steps (1) through (3) as necessary for any parts that were removed.
(1)
Install atomizer (18) in air cross connection (19).
(2)
Place tube fitting (17) on tubing (2), and install tubing on atomizer (18) with tube fitting. Tighten tube fitting
approximately one turn after it is finger tight.
Change 1
20-45