• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
OVERHEAT AND TEMPERATURE SENSORS REPLACEMENT. - Continued
OVERHEAT AND TEMPERATURE SENSORS REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  701    702    703    704    705  706  707    708    709    710    711  
img
. . . . . . . . . . . . .
TM 5-2420-230-24-1
(5)
Install air blower cover (8) on air blower (10) with three screws (9).
(6)
Install grommet (7) and cap (6) on fuel line (5) and air blower cover (8).
(7)
Install hose (3) on fuel line (5) and glow pin connection (4) with two cable ties (2).
(8)
Install exhaust cover (1).
c. Follow-On Maintenance.
(1)
Install water pump (Para 20-12).
(2)
Install control unit (Para 20-7).
END OF TASK
20-12. WATER PUMP REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Tools and Special Tools
Equipment Conditions
Tool kit, common no. 2, Item 36, Appendix B
TM or Para
Condition Description
Tool kit, general mechanics, Item 38, Appendix B
Para 20-5
Arctic heater removed.
Materials/Parts
Drawings Required
O-ring, Item 132.3, Appendix D (2)
TM 5-2420-230-24P Figure 207
O-ring, Item 153.1, Appendix D
Tags, identification, Item 63, Appendix C
Estimated Time to Complete Task
Ties, cable, Item 68, Appendix C
Refer to MAC in Appendix B
Personnel Required
MOS 62B, Construction Equipment Repairer
Change 1
20-42