TM 5-2420-230-24-1
13.
Using the four (4) longest mounting bolts,
tighten the bearing cap to the housing and
torque to specifications (Figure 135).
IMPORTANT:
If the bearing cap will not sit flush on the
housing, be sure the bearing cap seal ring or
tetra seal has not slipped out of place.
Figure 135
14.
Locate the timing mark on the piston rack and
center the timing mark in the pinion bore of
the housing by turning the actuating shaft.
(Figure 136).
Figure 136
15.
Install the sector shaft in the piston rack in
the pinion bore. Coat the end of the sector
shaft with grease to prevent seal damage.
IMPORTANT:
The single timing mark on the sector shaft
must line up between the two timing marks
on the piston rack (Figure 137).
Figure 137
K-94