TM 5-2420-230-24-2
L-36. OIL PUMP REPLACEMENT.
This Task Covers:
a. Removal
b. Inspection
c. Cleaning
d. Installation
e. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Tools and Special Tools
Equipment Conditions
Field maintenance, basic, Item 23, Appendix B
TM or Para
Condition Description
Tool kit, common no. 2, Item 36, Appendix B
Camshaft removed.
Tool kit, general mechanics, Item 38, Appendix B
Materials/Parts
Drawings Required
Oil, lubricating, OE/HDO-30, Item 44, Appendix C
Solvent, degreasing, Item 58, Appendix C
Estimated Time to Complete
Personnel Required
Refer to MAC in Appendix B
MOS 62B, Construction Equipment Repairer
a. Removal.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
b. Inspection.
c. Cleaning.
Degreasing Solvent (MIL-PRF-680) is toxic and flammable. Keep away from heat or flame. Never
smoke when using solvent. The flashpoint for Type II Degreasing Solvent is 141 F (61 C). Wear
protective goggles, face shield, and gloves; use only in a well-ventilated area; avoid contact with
skin, eyes, and clothes; and do not breathe vapors. Failure to comply may result in injury or death
to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately
flush eyes with water and get immediate medical attention.
Adhesives, solvents, and sealing compounds burn easily and give off vapors that are harmful to the
skin and clothing. To avoid injury or death, keep away from open fire when using these materials,
and use only in well-ventilated areas. If adhesives, solvents, or sealing compounds contact the skin
or clothing, wash immediately with soap and water, and rinse thoroughly. Failure to comply may
result in injury or death to personnel.
Change 1