PISTON AND ROD ASSEMBLIES REPLACEMENT.
CYLINDER BLOCK REPAIR.

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  42    43    44    45    46  47  48    49    50    51    52  
img
. . . . . . . .
TM 5-2420-230-24-2
L-39. CRANKSHAFT REPLACEMENT.
This Task Covers:
a. Removal
b. Cleaning
c. Inspection
d. Installation
e. Adjustment
f. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Personnel Required
None
MOS 62B, Construction Equipment Repairer (2)
Tools and Special Tools
References
Field maintenance, basic, Item 23, Appendix B
None
Tool kit, common no. 2, Item 36, Appendix B
Equipment Conditions
Tool kit, general mechanics, Item 38, Appendix B
TM or Para
Condition Description
Wear sleeve installation tool, Item 41, Appendix B
Para L-38
Piston and rod assemblies
removed.
Materials/Parts
Cloth, crocus, Item 9, Appendix C
Drawings Required
Grease, lithium, Item 34, Appendix C
TM 5-2420-230-24P Figure 3
Oil, lubricating, OE/HDO-30, Item 44, Appendix C
Solvent, degreasing, Item 58, Appendix C
Estimated Time to Complete
Refer to MAC in Appendix B
Bearing set, sleeve, Item 24, Appendix D
a. Removal.
Refer to page L-128 for removal.
b. Cleaning.
Degreasing Solvent (MIL-PRF-680) is toxic and flammable. Keep away from heat or flame. Never
smoke when using solvent. The flashpoint for Type II Degreasing Solvent is 141 F (61 C). Wear
protective goggles, face shield, and gloves; use only in a well-ventilated area; avoid contact with
skin, eyes, and clothes; and do not breathe vapors. Failure to comply may result in injury or death
to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately
flush eyes with water and get immediate medical attention.
Adhesives, solvents, and sealing compounds burn easily and give off vapors that are harmful to the
skin and clothing. To avoid injury or death, keep away from open fire when using these materials,
and use only in well-ventilated areas. If adhesives, solvents, or sealing compounds contact the skin
or clothing, wash immediately with soap and water, and rinse thoroughly. Failure to comply may
result in injury or death to personnel.
Refer to page L-229 for cleaning.
c. Inspection.
Refer to page L-229 for inspection.
L-46