TM 5-3805-294-10
0021
REMOVING THE COMPACTOR - Continued
23.
Open two auxiliary circuit shutoff valves (Figure 23, Item 6).
3
4
2
6
1
5
3
HYEX03411
Figure 23. Close Hydraulic Thumb Circuit.
24.
Remove retaining pin (Figure 23, Item 2) from pin (Figure 23, Item 3).
WARNING
Keep hands away from pin and alignment holes while thumb is being moved. Only use prybar
to push pin. Failure to comply may result in injury or death to personnel.
NOTE
Thumb may need to be repositioned multiple times with slight movements of the cylinder until
proper alignment of thumb to arm is achieved in order for pin to slide completely through.
25.
With the aid of an assistant, extend or retract thumb cylinder (Figure 23, Item 1), as needed, while using prybar
to remove pin (Figure 23, Item 3) from thumb lock position (Figure 23, Item 5).
26.
Install pin (Figure 23, Item 3) in storage position (Figure 23, Item 4).
27.
Install retaining pin (Figure 23, Item 2) to pin (Figure 23, Item 3).
28.
END OF TASK
END OF WORK PACKAGE