TM 5-3805-294-23-1
0048
Table 1. DTC 611.04 - Injector Shorted to Voltage Source - Continued.
Test or Inspection
Corrective Action
Malfunction
1.
If less than 1 kohms, replace
20.
Short Circuit
engine wiring harness.
Between Engine
3, WP 0369) between engine
Wiring Harness
wiring harness connector J01
(Volume 4, WP 0510) Restore
Connector J01
socket G2 and all other
machine to original condition
Socket G2 and All
sockets on engine wiring
and perform Harness
Other Sockets on
harness connector J01
Diagnostic Mode Test.
Engine Wiring
(Volume 5, WP 0800, Figure
(Volume 3, WP 0345)
Harness Connector
46) EXCEPT the following
2.
If greater than 1 kohms,
J01.
sockets:
proceed to Malfunction 21.
Socket A1.
Socket B1.
Socket C1.
Socket D1.
Socket E1.
Socket F1.
1.
Replace ECU. (Volume 4,
21.
ECU is Faulty.
WP 0508)
2.
Reconnect all connectors.
3.
Turn key switch to ON position,
but DO NOT START ENGINE
(TM 5-3805-294-10). (Volume
5, WP 0794)
4.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0362)
5.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0362)
6.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0362)
7.
Select Diagnostics tab, then
select Connected Diagnostic
Trouble Codes. (Volume 3,
WP 0362)
8.
Refresh DTCs. (Volume 3,
WP 0362)
9.
Select the Readings tab, then
select Connected Data
Points. (Volume 3, WP 0363)
0048-9